Design High Performance Centrifugal Compressor Vaned Diffusers
Posted Wed June 07, 2017 @05:36PM
Print version Email story Tweet story
Application The design of the vaned diffuser of a centrifugal compressor is still based on a considerable amount of empiricism in its design methodology. Parameters such as area ratio and blockage, which are more relevant to conical diffusers, are used in conventional design practice.

Sponsor CFD Review

The particle paths predicted by a 3D CFD code for a conventionally designed vaned diffuser are presented in the figures below. The particles are colour coded depending on their point of origin, varying from blue at the hub to red at the tip as shown by the legend.

vane diffuser

The particle paths indicate a complicated 3D flow pattern in the diffuser, and in particular the presence of a corner separation at the hub. This is due to the accumulation of low momentum fluid at the hub pressure surface corner, which then undergoes a strong positive pressure gradient. In order to improve the pressure recovery in the diffuser, TURBOdesign1 was used to re-design the vanes using the loading distribution.

The flow leaving the (conventionally designed) impeller is non-uniform with a high velocity at the hub and a low (almost stagnant) velocity near the shroud wall. In the TURBOdesign1, predicted particle paths for the conventionally designed impeller.

The predicted particle paths for the impeller designed by TURBOdesign1 redesign, a fore-loaded distribution is used at the hub to increase diffusion, and aft-loading at the shroud is employed to avoid any flow separation.

Download the publication to read in full.

[ Post Comment ]

New Mentor FloTHERM XT Release Simulates Complex Geometries with Ease, Speed and Accuracy | Best Practices in Combustion CFD III - Gas Turbines & Explosions  >

 

 
CFD Review Login
User name:

Password:

Create an Account

Related Links
  • publication
  • TURBOdesign1
  • More on Application
  • This discussion has been archived. No new comments can be posted.

    Never commit yourself! Let someone else commit you. All content except comments
    ©2022, Viable Computing.

    [ home | submit story | search | polls | faq | preferences | privacy | terms of service | rss  ]